SERVICE Sp problem Trouble arrow Sc Error +RESET problem arrow Konica c252 Reset +Alerts, cs171, cs172 προειδοποιησεις P21



Konica c252 Reset +Alerts, cs171, cs172 προειδοποιησεις P21
 
Price per Unit (τεμ.): Offer a price you like

c252 Reset +Alerts     WARNINGS       προειδοποιησεις......

 RESET ERROR CODE ...CLEAR CODE....as follows...

μπορειτε να κανετε  ρεσετ του κωδικου ως εξης...

Ακολουθηστε με την σειρα....

Κλειστε το διακοπτη (SUB) που ειναι ψηλα,  δεξια.... και τον εσωτερικο(πορτα εμπρος, αριστερα...) για 5''

ΚΡΑΤΗΣΤΕ ΠΑΤΗΜΕΝΟ συνεχως... Το ΠΛΗΚΤΡΟ  zahler/ΜΕΤΡΗΤΗΣ, counter

... και Ανοιξτε τον κατω διακοπτη, κλειστε την εμπρος πορτα,

Ανοιξτε τον πανω διακοπτη, .... περιμενετε εως να γραψει στην οθονη ... TROUBLE RESET

....πατηστε το ... ok

  ...και μετα Κλειστε για   5''......και ανοιξτε...τον κατω διακοπτη..... εσωτερικο

............

 counter key, Counter, details stop  0 0 stop 0 1 >>>service mode

,....

 Konica c252 clean + adjust... ...


c250, c252 GRADUATION Adjustment

......................

 All codes

 

C2551 Abnormally low toner density detected cyan TCR sensor

......

 c250 c252 cs171 cs172 errors....

  c252 error ALL  A +Resets AYTO!

  c252 error ALL  B ... P5 c5102 errors+

error CB003  occures.... if FK-502 board removed only.... (fax board) set it on Service mode

 http://www.copytechnet.com/forums/tags/c252.html

 ..................Ναι συμβαίνει συχνά, είναι βαριά αρχεία.

 Troubleshooting bizhub C250/C252
16.1.1 Alert list
• If an image stabilization or Scanner fault occurs, the corresponding warning code
appears.

 

αν χρειαζεται καποιο τονερ.... δειχνει.... Y  C  M  K toner need to change soon...

μπορει να δειξει κωδικο λαθους...αν αργησετε να αλλαξετε καποιο τονερ....!!!

C2557, Low K toner,  locked hole,  or HV short

 

Code Item Description
S-1 CCD clamp gain adjustment failure • It is detected that the CCD clamp gain adjustment
value is faulty.
P-5 IDC Sensor (Front) failure  (cup of sensor is fault - broken - no spring >>check 30'min)

in this case -no Graduation!!! is possible!!!    clean 2 sensors

• All outputs of Sensor photoreceiver section from the
detection point (unprinted surface on the Image Transfer
Belt) are 0.5 V or less or 4.3 V or more at output
checking during IDC/Registration Sensor adjustment.
• All outputs of Sensor photoreceiver section from the
detection point (unprinted surface on the Image Transfer
Belt) are 1.9 V or less or 4.4 V or more at density
setting during IDC/Registration Sensor adjustment.
• The output of Sensor photoreceiver section from the
detection point (toner pattern on the Image Transfer
Belt) is 1.0 V or less after the adjustment.


P-28 IDC Sensor (Back) failure
P-6 Cyan Imaging Unit failure • All density readings taken from the density pattern produced
on the Transfer Belt are 0.5 g/m2 (IDC Sensor
photoreceiver output) or less during max. density
adjustment (Vg/Vdc adjustment).
• All density readings taken from the density pattern produced
on the Transfer Belt are 4.5 g/m2 (IDC Sensor
Photoreceiver output) or more during max. density
adjustment (Vg/Vdc adjustment.)


P-7 Magenta Imaging Unit failure
P-8 Yellow Imaging Unit failure
P-9 Black Imaging Unit failure


P-21 Color Shift Test Pattern failure • The number of points detected in the main scan direction
is more or less than the specified value during
main scan direction registration correction.  clean 2 ID transfer + change belt, Graduation adj...
• The number of points detected in the Sub Scan Direction
is more or less than the specified value during sub
scan direction registration correction.

  • READY TO SCAN but not Green stable key, only blinks green, so not start is possible,
  • think about CB PWM, or connection with scann unit cable at the right...


P-22 Color Shift Adjust failure • The color shift amount is greater than the specified
range during main scan direction registration correction.
• The color shift amount is greater than the specified
range during sub scan direction registration correction.
• The skew correction amount is greater than the specified
value.


P-26 1st Image Transfer ATVC (K) failure • An abnormal average value is detected during an
adjustment of the first image transfer ATVC value of
Black.
P-27 2nd Image Transfer ATVC failure • An abnormal average value is detected during an
adjustment of the second image transfer ATVC value.
P-29 1st Image Transfer ATVC (color)
failure
• An abnormal average value is detected during an
adjustment of the first image transfer ATVC value of
color.


P-30 Color PC Drum Sensor malfunction • The output from the Color PC Drive Main and Sub Sensors
remains unchanged for a continuous period of
1,000 ms while the Color PC Drum Motor is turning stably
and the Lock signal is active (LOW-0).
P-31 Black PC Drum Sensor malfunction • The output from the Black PC Drive Main and Sub Sensors
remains unchanged for a continuous period of
1,000 ms while the Main Motor is turning stably

 

 

2015-01-02 

 16.2 Solution
16.2.1 S-1: CCD clamp/gain adjustment failure
16.2.2 P-5: IDC Sensor (Front) failure
16.2.3 P-28 IDC Sensor (Back) failure
Relevant Electrical Parts
Scanner Assy CCD Sensor Board (PWB-A)
Image Processing Board (PWB-C)
Step Action
1 Correct the harness connection between PWB-A and PWB-C if faulty.
2 Check for possible extraneous light and correct as necessary.
3 Clean the lens, mirrors, CCD surface, and shading sheet if dirty
4 Correct reflective mirror of the Scanner if faulty, or change Scanner.
5 Change PWB-A.
6 Change PWB-C.
Relevant Electrical Parts
IDC / Registration Sensor /1 (SE1)
IDC / Registration Sensor /2 (SE2)
Mechanical Control Board (PWB-M)
High Voltage Unit (HV1)
Image Transfer Belt Unit
Step Action
1 Wipe clean the surface of the Transfer Belt with a soft cloth, if it is dirty
2 Change the Image Transfer Belt Unit if the Transfer Belt is damaged.
3 Reinstall or reconnect SE1 or SE2 if it is installed or connected improperly.
4 Clean SE1 or SE2 if it is dirty
5 Check the HV1 connector for proper connection and correct as necessary.
6
Open and close the Front Door, run an image stabilization sequence, and select [State Confirmation]
→ [Level History 1] to check the IDC value.
IDC1: SE1, IDC2: SE2
If the value is 1.0 V or less, change SE1 or SE2.
7 Change PWB-M
Field Service Ver. 3.0 Aug. 2006 16. Malfunction code
417


Troubleshooting bizhub C250/C252
16.2.4 P-6: Cyan Imaging Unit failure
16.2.5 P-7: Magenta Imaging Unit failure
16.2.6 P-8: Yellow Imaging Unit failure
16.2.7 P-9: Black Imaging Unit failure
16.2.8 P-21: Color Shift Test Pattern failure
16.2.9 P-22: Color Shift Adjust failure
Relevant Electrical Parts
Imaging Unit /C
Imaging Unit /M
Imaging Unit /Y
Imaging Unit /K
Image Transfer Belt Unit
High Voltage Unit (HV1)


Step Action
1
Select [Imaging Process Adjustment] → [D Max Density] and, if the setting value is negative,
readjust.
2 Check the drive transmission portion of the Imaging Unit and correct as necessary.
3
Clean the IDC / Registration Sensor /1 (SE1) or IDC / Registration Sensor /2 (SE2) window if
dirty.
4 Clean the contact of the Imaging Unit connector if dirty.
5 Check the HV1 connector for proper connection and correct as necessary.
6 Change Imaging Unit.
7 Change the Image Transfer Belt Unit.


Relevant Electrical Parts
Image Transfer Belt Unit
Step Action
1 Wipe clean the surface of the Transfer Belt with a soft cloth, if it is dirty.
2 Change the Image Transfer Belt Unit if the Transfer Belt is damaged.
Relevant Electrical Parts
IDC / Registration Sensor /1 (SE1) IDC / Registration Sensor /2 (SE2)
Step Action
1 Slide out the Imaging Unit and reinstall it in position.
2 Reinstall or reconnect SE1 or SE2 if it is installed or connected improperly.
3 Check the Vertical Transport Guide for installed position and correct as necessary

 

2015-01-02 


Availability

In Stock: 1

Usually ships in:

on-order.gif


Last Updated: