RESET error Codes + arrow Ricoh 470w sc441 drive overLOAD



Ricoh 470w sc441 drive overLOAD
 
Price per Unit (τεμ.): Offer a price you like

Ricoh 470w sc441  drive overLOAD

 

hi............
 
I think that you have  drive overLOAD on moving Dev....
check Developer Unit Drive ...moving  belt or motor is out

sc 441  moter

SC441: Development drive motor lock
Definition: D
No. Meaning
SC441-1 Development drive motor lock signal is low longer than 5 s when the
development motor stops.
SC441-2 Development drive motor lock signal is high longer than 5 s when the
development motor rotates.
Possible Cause
Drive mechanism overload    check it
• Motor defective                      test it with program test
• Motor disconnected                  check it


 ...................

 